Hydroelectric Plants

Removal of contaminants from process fluids ensure that each piece of equipment remains working with the highest possible efficiency

Total Reliability

Optimize Hydroelectric Plant Performance With Advanced Industrial Fluid Filtration Elements

Hydroelectric turbines convert the potential energy stored in water to mechanical energy by rotating a paddle-wheel or propeller-type runner on the turbine. This rotating mechanical energy is used to turn an electric generator, producing electrical energy. Hydraulic fluid cleanliness of the turbine governor system is critical to maintain the proper rotational speed of the turbine. The inlet valve hydraulic power units and turbine bearing lube systems also require proper lubrication for reliable performance. Our industrial fluid filtration elements improve lubrication and hydraulic fluid quality to optimize hydroelectric power plant performance and maximize productive uptime.

 

How it works

 

Filtration media is constructed of inert, organic fibers that are impregnated and bonded with epoxy resins. The media is protected and strengthened by Pall’s patented helical wrap pleat support system and composite element structure. The outer helical wrap binds tightly to each pleat for rigid and uniform spacing. This arrangement minimizes pleat flexing and media damage under varying flow, cold start, shock, vibration, and pressure surge conditions. Built in flow-channels also prevent media blind off during pressure drop increases. These unique design elements ensure maximum particulate uptake and highly efficient contaminant distribution throughout the filter media, at all stages of filter life. Filter media is available in coreless filter options, with a choice of corrosion protected or polymer end caps for an environmentally-friendly design.

 

Proprietary plastic upstream and downstream support layers featuring Pall’s stress-resistant technology (SRT) provide media with up to 210 bard (3045 psid) of additional physical protection. This technology also protects media from static charging/discharging, which can lead to extensive operational problems. 

Contact our team of filtration experts for more information on improving the efficiency of your processes.

 

Country
  • Afghanistan
  • Albania
  • Algeria
  • American Samoa
  • Andorra
  • Angola
  • Anguilla
  • Antarctica
  • Antigua and Barbuda
  • Argentina
  • Aruba
  • Australia
  • Austria
  • Bahamas
  • Bahrain
  • Bangladesh
  • Barbados
  • Belgium
  • Belize
  • Benin
  • Bermuda
  • Bhutan
  • Bolivia
  • Botswana
  • Brazil
  • British Indian Ocean Territory
  • Brunei Darussalam
  • Bulgaria
  • Burkina Faso
  • Burundi
  • Cambodia
  • Cameroon
  • Canada
  • Cape Verde
  • Cayman Islands
  • Chad
  • Chile
  • China
  • Christmas Island
  • Cocos (Keeling) Islands
  • Colombia
  • Comoros
  • Cook Islands
  • Costa Rica
  • Croatia
  • Cuba
  • Cyprus
  • Czech Republic
  • Denmark
  • Djibouti
  • Dominica
  • Dominican Republic
  • Ecuador
  • Egypt
  • El Salvador
  • Equatorial Guinea
  • Eritrea
  • Estonia
  • Ethiopia
  • Falkland Islands
  • Faroe Islands
  • Fiji
  • Finland
  • France
  • French Guiana
  • French Polynesia
  • French Southern Territories
  • Gabon
  • Gambia
  • Germany
  • Ghana
  • Gibraltar
  • Greece
  • Greenland
  • Grenada
  • Guadeloupe
  • Guam
  • Guatemala
  • Guinea
  • Guinea-Bissau
  • Guyana
  • Haiti
  • Honduras
  • Hong Kong
  • Hungary
  • Iceland
  • India
  • Indonesia
  • Iraq
  • Ireland
  • Israel
  • Italy
  • Jamaica
  • Japan
  • Jordan
  • Kenya
  • Kiribati
  • Kuwait
  • Laos
  • Latvia
  • Lebanon
  • Lesotho
  • Liberia
  • Libya
  • Liechtenstein
  • Lithuania
  • Luxembourg
  • Macao
  • Madagascar
  • Malawi
  • Malaysia
  • Maldives
  • Mali
  • Malta
  • Marshall Islands
  • Martinique
  • Mauritania
  • Mauritius
  • Mayotte
  • Mexico
  • Monaco
  • Mongolia
  • Montserrat
  • Morocco
  • Mozambique
  • Myanmar
  • Namibia
  • Nauru
  • Nepal
  • Netherlands
  • Netherlands Antilles
  • New Caledonia
  • New Zealand
  • Nicaragua
  • Niger
  • Nigeria
  • Niue
  • Norfolk Island
  • Northern Mariana Islands
  • Norway
  • Oman
  • Pakistan
  • Palau
  • Palestinian Territory
  • Panama
  • Papua New Guinea
  • Paraguay
  • Peru
  • Philippines
  • Poland
  • Portugal
  • Puerto Rico
  • Qatar
  • Romania
  • Rwanda
  • Samoa
  • Saudi Arabia
  • Senegal
  • Seychelles
  • Sierra Leone
  • Singapore
  • Slovakia
  • Slovenia
  • Solomon Islands
  • Somalia
  • South Africa
  • Spain
  • Sri Lanka
  • St Kitts and Nevis
  • St Lucia
  • Sudan
  • Suriname
  • Swaziland
  • Sweden
  • Switzerland
  • Taiwan
  • Thailand
  • Togo
  • Tonga
  • Trinidad and Tobago
  • Tunisia
  • Turkey
  • Tuvalu
  • Uganda
  • United Arab Emirates
  • United Kingdom
  • United States
  • Uruguay
  • Vanuatu
  • Venezuela
  • Vietnam
  • Virgin Islands
  • Western Sahara
  • Yemen
  • Zambia
  • Zimbabwe
Choose Industry
  • Aerospace
  • Biotech
  • Chemicals & Polymers
  • Food & Beverage
  • Industrial Manufacturing
  • Laboratory
  • Medical
  • Microelectronics
  • Oil & Gas
  • Power & Utilities
Choose Support Type
  • General Inquiry
  • Pricing / Quotation
  • Technical Help
Would you like to receive more information about Pall’s products and services, and related products and services from Pall’s related companies?

By clicking the Submit button below and proceeding I confirm that I have reviewed and agree with the Terms of Use and the Privacy Policy.

Thank You

We will get in touch with you very shortly.

Total production

Filter media housings and vessels

Our LMO 1000 Style Series stainless steel filter housings provide superior and easy to install filter element protection. These housings feature secure closing mechanisms that prevent fluid bypass, and can accommodate pressures and temperatures of up to 69 bar and 121 °C.

 

The Ultipleat® SRT carbon steel Multi-Element Fabricated Vessels provide maximum filter element protection and augment media performance. These cageless and coreless elements fully protect media from physical damage and contamination, and facilitate flow rates from 1500L/min to 4500L/min.   

 

Filter media application in hydroelectric power generation

 

Recommended Pall filter assemblies are in-line, upstream of each proportional or directional valve, and on the pressure line of the hydraulic power units. This installation strategy ensures superior maintenance of hydraulic and lubrication fluid quality.

 

Installation of a Pall Reservoir Vent Filter in place of a conventional reservoir cap prohibits airborne contamination for additional fluid clarity in hydraulic power unit reservoirs. This improvement in fluid quality enhances overall system performance while lowering maintenance and repair costs.

 

Filter media application in hydroelectric power generation

 

Our hydroelectric industrial fluid filters provide a variety of cutting edge, industry specific fluid filtration options to achieve operating and maintenance savings. For more information, click here to see purchase information or talk to a Pall expert.   

Let’s connect.

Looking for more information? Our knowledgeable subject matter experts are ready to help. To learn more about our advanced and innovative filtration solutions, contact us today. Thank you and we look forward to assisting you shortly.